FAQ#085 - How many digital gauges in the same chain is possible to read with New Leonardo?

The theoretical maximum number of digital gauge (RS485, ModBus) that is possible to read with New Leonardo is 245 gauges (address from 1 to 254).

This is true only if the gauge is configured in Sisgeo laboratory in "Energy save" mode: the gauges wake-up and are powered one by one.

When the "Energy Save" mode is NOT active, the maximum number of digital gauges in the same chain that New Leonardo is able to read is 50.