{"id":21815,"date":"2023-07-24T18:00:48","date_gmt":"2023-07-24T16:00:48","guid":{"rendered":"https:\/\/sisgeo.com\/unkategorisiert\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"modified":"2023-07-24T18:00:48","modified_gmt":"2023-07-24T16:00:48","slug":"why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","title":{"rendered":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?"},"content":{"rendered":"\n<p>It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge.<\/p>\n\n\n\n<p>For example, suppose a 4-20mA gauge requires at least 12 V to operate correctly and the readout powered with 16 V. The voltage the gauge sees is the voltage supplied by the readout minus the voltage drop in the rest of the current loop. At 20 mA output, the voltage drop across the commonly used 100 ohm resistor is 2 V.<\/p>\n\n\n\n<p>When the voltage supplied by the readout is 16 V, this leaves 14 V for the gauge and everything is fine.<br>However, if the readout is powered with less than 14 V, at 20 mA current it will leave less than 12 V for the gauge. In this case, the output of the transmitter may be in error.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[577,704,499,478,475,613,582,586,658,662,677,680,529,483,532,616,619,592,465,674,622,628],"tags":[227],"class_list":["post-21815","post","type-post","status-publish","format-standard","hentry","category-analoges-ketteninklinometer","category-analoges-tiltmeter","category-convergence-extensometer-de","category-draht-extensometer","category-draht-fugenmesser","category-drive-in-piezometers-de","category-elektrische-ankerkraftmessdosen","category-elektrische-kraftmessdosen","category-erddruckmessdosen","category-flachpresse-flat-jack-testapparatur","category-h-level-messsystem","category-system-setzungsmesssystem","category-mexid-miniatur-mehrfach-bohrlochextensometer","category-mini-omnialog-4-kanal-datenlogger","category-mpbx-mehrfach-bohrlochextensometer","category-piezo-resistive-piezometers-de","category-removable-pressure-transducers-de","category-resistive-kraftmessdosen-fur-pfahllastversuche","category-rissmeter-und-fugenmesser","category-setzungspegel","category-titanium-piezometers-de","category-vented-pressure-transducers-de","tag-faq-de"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge?\" \/>\n<meta property=\"og:description\" content=\"It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-24T16:00:48+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?\",\"datePublished\":\"2023-07-24T16:00:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"},\"wordCount\":171,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"keywords\":[\"H\u00c4UFIG GESTELLTE FRAGEN\"],\"articleSection\":[\"Analoges Ketteninklinometer\",\"Analoges Tiltmeter\",\"Convergence extensometer\",\"Draht-Extensometer\",\"Draht-Fugenmesser\",\"Drive-in piezometers\",\"Elektrische Ankerkraftmessdosen\",\"Elektrische Kraftmessdosen\",\"Erddruckmessdosen\",\"Flachpresse (Flat jack) Testapparatur\",\"H-Level-Messsystem\",\"Mehrfach Setzungsmesssystem\",\"MEXID Miniatur-Mehrfach- Bohrlochextensometer\",\"Mini OMNIAlog 4-Kanal Datenlogger\",\"MPBX - Mehrfach-Bohrlochextensometer\",\"Piezo-resistive piezometers\",\"Removable pressure transducers\",\"Resistive Kraftmessdosen f\u00fcr Pfahllastversuche\",\"Rissmeter und Fugenmesser\",\"Setzungspegel\",\"Titanium piezometers\",\"Vented pressure transducers\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\",\"url\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\",\"name\":\"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#website\"},\"datePublished\":\"2023-07-24T16:00:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produkte\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"IPI In-Place-Neigungsmesser\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/ipi-in-place-inclinometers-de\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Analoges Ketteninklinometer\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/ipi-in-place-inclinometers-de\/analoges-ketteninklinometer\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/de\/#website\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","og_locale":"de_DE","og_type":"article","og_title":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge?","og_description":"It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]","og_url":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","og_site_name":"Sisgeo","article_published_time":"2023-07-24T16:00:48+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Staff Pipeline","Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?","datePublished":"2023-07-24T16:00:48+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"wordCount":171,"publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"keywords":["H\u00c4UFIG GESTELLTE FRAGEN"],"articleSection":["Analoges Ketteninklinometer","Analoges Tiltmeter","Convergence extensometer","Draht-Extensometer","Draht-Fugenmesser","Drive-in piezometers","Elektrische Ankerkraftmessdosen","Elektrische Kraftmessdosen","Erddruckmessdosen","Flachpresse (Flat jack) Testapparatur","H-Level-Messsystem","Mehrfach Setzungsmesssystem","MEXID Miniatur-Mehrfach- Bohrlochextensometer","Mini OMNIAlog 4-Kanal Datenlogger","MPBX - Mehrfach-Bohrlochextensometer","Piezo-resistive piezometers","Removable pressure transducers","Resistive Kraftmessdosen f\u00fcr Pfahllastversuche","Rissmeter und Fugenmesser","Setzungspegel","Titanium piezometers","Vented pressure transducers"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","url":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","name":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/#website"},"datePublished":"2023-07-24T16:00:48+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/rissmessgerate-und-fugenmessgerate\/rissmeter-und-fugenmesser\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/"},{"@type":"ListItem","position":2,"name":"Produkte","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/"},{"@type":"ListItem","position":3,"name":"IPI In-Place-Neigungsmesser","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/ipi-in-place-inclinometers-de\/"},{"@type":"ListItem","position":4,"name":"Analoges Ketteninklinometer","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/ipi-in-place-inclinometers-de\/analoges-ketteninklinometer\/"},{"@type":"ListItem","position":5,"name":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/de\/#website","url":"https:\/\/sisgeo.com\/de\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/de\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/21815","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/comments?post=21815"}],"version-history":[{"count":0,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/21815\/revisions"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/media?parent=21815"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/categories?post=21815"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/tags?post=21815"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}