{"id":21926,"date":"2023-07-24T16:03:21","date_gmt":"2023-07-24T14:03:21","guid":{"rendered":"https:\/\/sisgeo.com\/unkategorisiert\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/"},"modified":"2024-01-05T17:44:34","modified_gmt":"2024-01-05T16:44:34","slug":"why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/","title":{"rendered":"FAQ#076 &#8211; Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?"},"content":{"rendered":"\n<p>All SISGEO digitized instruments (IPIs, Tiltmeters, H-Level\u2026) use the RS-485 serial communication protocol<\/p>\n\n<p>The RS485 protocol contemplate a termination resistor.<\/p>\n\n<p>The recommended chain connection is point-to-point (multidropped) nodes as a bus mode (line). Star, ring or multiply network connection are not recommended. <\/p>\n\n<p>SISGEO dataloggers has already a termination resistor assembled (typically 120\u03a9). On the opposite side (sensors side) is necessary to mount a resistor on the last device of each chain. <\/p>\n\n<p>Without termination resistors, reflections of fast driver edges can cause multiple data edges and consequently data corruption. Termination resistors also reduce electrical noise sensitivity. The value of each termination resistor should be equal to the cable characteristic impedance (typically, 120 \u03a9 for twisted pairs and for only one chain).  <\/p>\n\n<p>SISGEO supply the correct termination resistor (120 \u03a9, 240 \u03a9, etc.), considering the number of the chains connected to the same master unit (logger):<\/p>\n\n<p>&#8211; N.1 digital chain connected to one logger (OMNIAlog, digital node, ecc..): N.1 resistance, value 120 \u03a9<br\/>&#8211; N.2 digital chains connected to one logger (OMNIAlog, digital node, ecc..): N.2 resistances, value 240 \u03a9 (one for each chain)<br\/>&#8211; N.3 digital chains connected to one logger (OMNIAlog, digital node, ecc..): N.3 resistances, value 360 \u03a9 (one for each chain)<br\/>&#8211; N.4 digital chains connected to one logger (OMNIAlog, digital node, ecc..): N.4 resistances, value 480 \u03a9 (one for each chain)<\/p>\n\n<p>The termination resistor must be connected on the appropriate sensor connector.<\/p>\n\n<p>At the following link an example scheme: <a href=\"https:\/\/drive.google.com\/file\/d\/0B7XUq8Asj7w7UjJiU1hpVUI0aXc\/view?resourcekey=0-nX0jRi1t8A_2pwfLyTSKrw\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">SCHEME<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>All SISGEO digitized instruments (IPIs, Tiltmeters, H-Level\u2026) use the RS-485 serial communication protocol The RS485 protocol contemplate a termination resistor. The recommended chain connection is point-to-point (multidropped) nodes as a bus mode (line). Star, ring or multiply network connection are not recommended. SISGEO dataloggers has already a termination resistor assembled (typically 120\u03a9). On the opposite [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[710,552,701,677,562,568,574,483,487],"tags":[227],"class_list":["post-21926","post","type-post","status-publish","format-standard","hentry","category-analoges-messbalken-tiltmeter","category-bh-profile-in-place-inclinometers-de","category-digitales-tiltmeter-mit-mems-sensoren","category-h-level-messsystem","category-horizontal-in-place-inclinometers-de","category-lt-inclibus-de","category-md-profile-array-de","category-mini-omnialog-4-kanal-datenlogger","category-omnialog-datenlogger","tag-faq-de"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?\" \/>\n<meta property=\"og:description\" content=\"All SISGEO digitized instruments (IPIs, Tiltmeters, H-Level\u2026) use the RS-485 serial communication protocol The RS485 protocol contemplate a termination resistor. The recommended chain connection is point-to-point (multidropped) nodes as a bus mode (line). Star, ring or multiply network connection are not recommended. SISGEO dataloggers has already a termination resistor assembled (typically 120\u03a9). On the opposite [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-24T14:03:21+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-05T16:44:34+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#076 &#8211; Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?\",\"datePublished\":\"2023-07-24T14:03:21+00:00\",\"dateModified\":\"2024-01-05T16:44:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\"},\"wordCount\":247,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"keywords\":[\"H\u00c4UFIG GESTELLTE FRAGEN\"],\"articleSection\":[\"Analoges Messbalken-Tiltmeter\",\"BH-Profile in-place Inclinometers\",\"Digitales Tiltmeter mit MEMS-Sensoren\",\"H-Level-Messsystem\",\"Horizontal In Place Inclinometers\",\"LT-Inclibus\",\"MD-Profile array\",\"Mini OMNIAlog 4-Kanal Datenlogger\",\"OMNIAlog Datenlogger\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\",\"url\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\",\"name\":\"FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#website\"},\"datePublished\":\"2023-07-24T14:03:21+00:00\",\"dateModified\":\"2024-01-05T16:44:34+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produkte\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Neigungsmesser\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/neigungsmesser\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Analoges Messbalken-Tiltmeter\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/neigungsmesser\/analoges-messbalken-tiltmeter\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#076 &#8211; Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/de\/#website\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/","og_locale":"de_DE","og_type":"article","og_title":"FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?","og_description":"All SISGEO digitized instruments (IPIs, Tiltmeters, H-Level\u2026) use the RS-485 serial communication protocol The RS485 protocol contemplate a termination resistor. The recommended chain connection is point-to-point (multidropped) nodes as a bus mode (line). Star, ring or multiply network connection are not recommended. SISGEO dataloggers has already a termination resistor assembled (typically 120\u03a9). On the opposite [&hellip;]","og_url":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/","og_site_name":"Sisgeo","article_published_time":"2023-07-24T14:03:21+00:00","article_modified_time":"2024-01-05T16:44:34+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Staff Pipeline","Gesch\u00e4tzte Lesezeit":"1\u00a0Minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#076 &#8211; Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?","datePublished":"2023-07-24T14:03:21+00:00","dateModified":"2024-01-05T16:44:34+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/"},"wordCount":247,"publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"keywords":["H\u00c4UFIG GESTELLTE FRAGEN"],"articleSection":["Analoges Messbalken-Tiltmeter","BH-Profile in-place Inclinometers","Digitales Tiltmeter mit MEMS-Sensoren","H-Level-Messsystem","Horizontal In Place Inclinometers","LT-Inclibus","MD-Profile array","Mini OMNIAlog 4-Kanal Datenlogger","OMNIAlog Datenlogger"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/","url":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/","name":"FAQ#076 - Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/#website"},"datePublished":"2023-07-24T14:03:21+00:00","dateModified":"2024-01-05T16:44:34+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/datenlogger\/mini-omnialog-4-kanal-datenlogger\/why-it-is-necessary-add-a-termination-resistor-to-the-last-digitized-sensor-of-each-rs-485-chain\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/"},{"@type":"ListItem","position":2,"name":"Produkte","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/"},{"@type":"ListItem","position":3,"name":"Neigungsmesser","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/neigungsmesser\/"},{"@type":"ListItem","position":4,"name":"Analoges Messbalken-Tiltmeter","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/neigungsmesser\/analoges-messbalken-tiltmeter\/"},{"@type":"ListItem","position":5,"name":"FAQ#076 &#8211; Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/de\/#website","url":"https:\/\/sisgeo.com\/de\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/de\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/21926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/comments?post=21926"}],"version-history":[{"count":1,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/21926\/revisions"}],"predecessor-version":[{"id":21927,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/21926\/revisions\/21927"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/media?parent=21926"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/categories?post=21926"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/tags?post=21926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}