{"id":22066,"date":"2023-07-21T15:47:18","date_gmt":"2023-07-21T13:47:18","guid":{"rendered":"https:\/\/sisgeo.com\/unkategorisiert\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/"},"modified":"2024-01-05T18:42:18","modified_gmt":"2024-01-05T17:42:18","slug":"which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/","title":{"rendered":"FAQ#003 &#8211; Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#8217;s wire?"},"content":{"rendered":"\n<p>To fix the \u201cSUS\u201d optical sensor unit through the \u201cANS\u201d support, it is necessary that the direct pendulum\u2019s wire is at a distance of d=230 mm. from the wall.<\/p>\n\n<p>To achieve that, the direct pendulum\u2019s tank has to be placed at a distance of D=20 mm. from the wall: in this way is guaranteed that the pendulum\u2019s wire is exactly at the center of the \u201cSUS\u201d optical sensor unit.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>To fix the \u201cSUS\u201d optical sensor unit through the \u201cANS\u201d support, it is necessary that the direct pendulum\u2019s wire is at a distance of d=230 mm. from the wall. To achieve that, the direct pendulum\u2019s tank has to be placed at a distance of D=20 mm. from the wall: in this way is guaranteed that [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[520,597],"tags":[227],"class_list":["post-22066","post","type-post","status-publish","format-standard","hentry","category-elektronisches-lotmesssystem-telependulum","category-gewicht-und-schwimmlot","tag-faq-de"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#039;s wire? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#039;s wire?\" \/>\n<meta property=\"og:description\" content=\"To fix the \u201cSUS\u201d optical sensor unit through the \u201cANS\u201d support, it is necessary that the direct pendulum\u2019s wire is at a distance of d=230 mm. from the wall. To achieve that, the direct pendulum\u2019s tank has to be placed at a distance of D=20 mm. from the wall: in this way is guaranteed that [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-21T13:47:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-05T17:42:18+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#003 &#8211; Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#8217;s wire?\",\"datePublished\":\"2023-07-21T13:47:18+00:00\",\"dateModified\":\"2024-01-05T17:42:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\"},\"wordCount\":98,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"keywords\":[\"H\u00c4UFIG GESTELLTE FRAGEN\"],\"articleSection\":[\"Elektronisches Lotmesssystem - Telependulum\",\"Gewicht und schwimmlot\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\",\"url\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\",\"name\":\"FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum's wire? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#website\"},\"datePublished\":\"2023-07-21T13:47:18+00:00\",\"dateModified\":\"2024-01-05T17:42:18+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Produkte\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Abgek\u00fcndigt\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/discontinued-de\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Elektronisches Lotmesssystem - Telependulum\",\"item\":\"https:\/\/sisgeo.com\/de\/category\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#003 &#8211; Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#8217;s wire?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/de\/#website\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/de\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/de\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/de\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum's wire? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/","og_locale":"de_DE","og_type":"article","og_title":"FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum's wire?","og_description":"To fix the \u201cSUS\u201d optical sensor unit through the \u201cANS\u201d support, it is necessary that the direct pendulum\u2019s wire is at a distance of d=230 mm. from the wall. To achieve that, the direct pendulum\u2019s tank has to be placed at a distance of D=20 mm. from the wall: in this way is guaranteed that [&hellip;]","og_url":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/","og_site_name":"Sisgeo","article_published_time":"2023-07-21T13:47:18+00:00","article_modified_time":"2024-01-05T17:42:18+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"Staff Pipeline"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#003 &#8211; Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#8217;s wire?","datePublished":"2023-07-21T13:47:18+00:00","dateModified":"2024-01-05T17:42:18+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/"},"wordCount":98,"publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"keywords":["H\u00c4UFIG GESTELLTE FRAGEN"],"articleSection":["Elektronisches Lotmesssystem - Telependulum","Gewicht und schwimmlot"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/","url":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/","name":"FAQ#003 - Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum's wire? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/de\/#website"},"datePublished":"2023-07-21T13:47:18+00:00","dateModified":"2024-01-05T17:42:18+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/de\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/which-are-the-needed-conditions-to-use-the-ans-adjustable-support-for-tel-310s-if-you-need-to-monitor-the-direct-pendulums-wire\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/de\/geotechnische-und-strukturelle-instrumentierung-fuer-shm\/"},{"@type":"ListItem","position":2,"name":"Produkte","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/"},{"@type":"ListItem","position":3,"name":"Abgek\u00fcndigt","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/discontinued-de\/"},{"@type":"ListItem","position":4,"name":"Elektronisches Lotmesssystem - Telependulum","item":"https:\/\/sisgeo.com\/de\/category\/products-de-2\/discontinued-de\/elektronisches-lotmesssystem-telependulum\/"},{"@type":"ListItem","position":5,"name":"FAQ#003 &#8211; Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum&#8217;s wire?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/de\/#website","url":"https:\/\/sisgeo.com\/de\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/de\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/de\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/de\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/de\/","logo":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/de\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/de\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/de\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/22066","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/comments?post=22066"}],"version-history":[{"count":1,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/22066\/revisions"}],"predecessor-version":[{"id":22067,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/posts\/22066\/revisions\/22067"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/media?parent=22066"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/categories?post=22066"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/de\/wp-json\/wp\/v2\/tags?post=22066"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}