{"id":21325,"date":"2023-07-24T16:51:04","date_gmt":"2023-07-24T14:51:04","guid":{"rendered":"https:\/\/sisgeo.com\/sin-categorizar\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/"},"modified":"2024-01-05T10:03:26","modified_gmt":"2024-01-05T09:03:26","slug":"hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/","title":{"rendered":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?"},"content":{"rendered":"\n<p>El OMNIAlog est\u00e1 equipado con una memoria microSD de 2GB. Esta memoria permite guardar un n\u00famero muy elevado de lecturas. Por esta raz\u00f3n, es necesario tener en cuenta lo siguiente:  <\/p>\n\n<ul class=\"wp-block-list\">\n<li>Si hay numerosas lecturas guardadas en la memoria del registrador de datos, el tiempo de exportaci\u00f3n tanto con llave USB y a trav\u00e9s de la p\u00e1gina web puede llevar mucho tiempo. Por ejemplo, para exportar con una llave USB aproximadamente 5.000.000 puntos de datos con sus eventos relacionados, registros y alertas, el OMNIAlog necesita 4-5 horas. <\/li>\n\n\n\n<li>Las hojas de c\u00e1lculo tradicionales tienen algunos l\u00edmites en el n\u00famero de l\u00edneas y columnas de gesti\u00f3n. Por ejemplo, Microsoft Excel y Open Office gestiona hasta 1.048.576 l\u00edneas y 16.384 columnas. Utilizando el mismo ejemplo del punto anterior, el archivo de medici\u00f3n (log mediciones) supera ampliamente estos l\u00edmites. Por lo tanto, al abrir el archivo, no se mostrar\u00e1n todas las mediciones.   <\/li>\n\n\n\n<li>Si la exportaci\u00f3n necesita un per\u00edodo de tiempo que es superior al tiempo de adquisici\u00f3n configurado, las adquisiciones planificadas no se realizan.<\/li>\n<\/ul>\n\n<p>Por lo tanto SISGEO sugiere descargar peri\u00f3dicamente los datos y,posteriormente, borrarlos de la memoria OMNIAlog. De esta manera se garantiza una descarga de datos eficiente. <\/p>\n","protected":false},"excerpt":{"rendered":"<p>El OMNIAlog est\u00e1 equipado con una memoria microSD de 2GB. Esta memoria permite guardar un n\u00famero muy elevado de lecturas. Por esta raz\u00f3n, es necesario tener en cuenta lo siguiente: Por lo tanto SISGEO sugiere descargar peri\u00f3dicamente los datos y,posteriormente, borrarlos de la memoria OMNIAlog. De esta manera se garantiza una descarga de datos eficiente.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[488,485],"tags":[230],"class_list":["post-21325","post","type-post","status-publish","format-standard","hentry","category-datalogger-omnialog","category-mini-omnialog-datalogger-es","tag-faq-es"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?\" \/>\n<meta property=\"og:description\" content=\"El OMNIAlog est\u00e1 equipado con una memoria microSD de 2GB. Esta memoria permite guardar un n\u00famero muy elevado de lecturas. Por esta raz\u00f3n, es necesario tener en cuenta lo siguiente: Por lo tanto SISGEO sugiere descargar peri\u00f3dicamente los datos y,posteriormente, borrarlos de la memoria OMNIAlog. De esta manera se garantiza una descarga de datos eficiente.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-24T14:51:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-01-05T09:03:26+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?\",\"datePublished\":\"2023-07-24T14:51:04+00:00\",\"dateModified\":\"2024-01-05T09:03:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\"},\"wordCount\":230,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"keywords\":[\"PREGUNTAS M\u00c1S FRECUENTES\"],\"articleSection\":[\"Datalogger OMNIAlog\",\"Mini OMNIAlog datalogger\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\",\"url\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\",\"name\":\"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#website\"},\"datePublished\":\"2023-07-24T14:51:04+00:00\",\"dateModified\":\"2024-01-05T09:03:26+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Productos\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Dataloggers\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/dataloggers-es\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Datalogger OMNIAlog\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/dataloggers-es\/datalogger-omnialog\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/es\/#website\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/","og_locale":"es_ES","og_type":"article","og_title":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?","og_description":"El OMNIAlog est\u00e1 equipado con una memoria microSD de 2GB. Esta memoria permite guardar un n\u00famero muy elevado de lecturas. Por esta raz\u00f3n, es necesario tener en cuenta lo siguiente: Por lo tanto SISGEO sugiere descargar peri\u00f3dicamente los datos y,posteriormente, borrarlos de la memoria OMNIAlog. De esta manera se garantiza una descarga de datos eficiente.","og_url":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/","og_site_name":"Sisgeo","article_published_time":"2023-07-24T14:51:04+00:00","article_modified_time":"2024-01-05T09:03:26+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Staff Pipeline","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?","datePublished":"2023-07-24T14:51:04+00:00","dateModified":"2024-01-05T09:03:26+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/"},"wordCount":230,"publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"keywords":["PREGUNTAS M\u00c1S FRECUENTES"],"articleSection":["Datalogger OMNIAlog","Mini OMNIAlog datalogger"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/","url":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/","name":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/#website"},"datePublished":"2023-07-24T14:51:04+00:00","dateModified":"2024-01-05T09:03:26+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/dataloggers-es\/mini-omnialog-datalogger-es\/hay-alguna-precaucion-a-adoptar-por-el-numero-de-mediciones-guardadas-en-la-memoria-omnialog-mini-omnialog\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/"},{"@type":"ListItem","position":2,"name":"Productos","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/"},{"@type":"ListItem","position":3,"name":"Dataloggers","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/dataloggers-es\/"},{"@type":"ListItem","position":4,"name":"Datalogger OMNIAlog","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/dataloggers-es\/datalogger-omnialog\/"},{"@type":"ListItem","position":5,"name":"FAQ#082 \u2013 \u00bfHay alguna precauci\u00f3n a adoptar por el n\u00famero de mediciones guardadas en la memoria OMNIAlog \/ Mini OMNIAlog?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/es\/#website","url":"https:\/\/sisgeo.com\/es\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/es\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/comments?post=21325"}],"version-history":[{"count":1,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21325\/revisions"}],"predecessor-version":[{"id":21326,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21325\/revisions\/21326"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/media?parent=21325"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/categories?post=21325"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/tags?post=21325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}