{"id":21801,"date":"2023-07-24T18:13:43","date_gmt":"2023-07-24T16:13:43","guid":{"rendered":"https:\/\/sisgeo.com\/sin-categorizar\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/"},"modified":"2024-09-13T12:04:21","modified_gmt":"2024-09-13T10:04:21","slug":"how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/","title":{"rendered":"FAQ#116 &#8211; How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?"},"content":{"rendered":"\n<p>Sisgeo digital instruments can operate in two powering modes: TIMED or ALWAYS-ON (for more information see <a href=\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/which-are-the-available-powering-modes-for-sisgeo-digital-sensors\/\" target=\"_blank\" rel=\"noreferrer noopener\">F.A.Q.#094<\/a>).<br>A string of mixed instruments consisting of TIMED gauges and ALWAYS-ON gauges cannot work.<br>The first thing to do is therefore to check that ALL connected instruments in your array are set to TIMED mode.<br>You can check the powering mode of your gauges in the calibration reports of each instrument as in the example below.<br>The numbers \u00ab3-3\u00bb after \u00abTIMED\u00bb are the \u00abwarming delay\u00bb and \u00abaddress delay\u00bb values to be entered in the APP wizard set-up page.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img fetchpriority=\"high\" decoding=\"async\" width=\"933\" height=\"586\" src=\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\" alt=\"\" class=\"wp-image-3774\" srcset=\"https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/TIMED_example.png 933w, https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/TIMED_example-300x188.png 300w, https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/TIMED_example-768x482.png 768w\" sizes=\"(max-width: 933px) 100vw, 933px\" \/><\/figure>\n\n\n\n<p>In order to correctly set-up the WR-Log app for reading a string of Sisgeo digital gauges in TIMED powering mode, please follow the next screenshot as example:<\/p>\n\n\n\n<p>&#8211; choose the protocol \u00abSisgeo v3\u00bb\u00a0(for uniaxial or biaxial gauges) or other \u00ab360\u00bb protocol for tri-axial gauges<br>&#8211; insert the correspondent Warming delay value (in our example 3)<br>&#8211; insert the correspondent Adress delay value (in our example 3)<br>&#8211; insert the addresses of the gauges in your string, separated by comma without any space, in ASCENDING order (do NOT inser the addresses in random order!)<br>NOTE: in TIMED mode, the reading time is about WARMING_DELAY x HIGHER_RS485_ADDRESS, in our case 3 x 20 = about 60 seconds.<br>So, if your string is composed by 20 gauges BUT with addresses from 200 to 220, the reading time is about 3 x 220 = 660 seconts (11 minutes) to read the same 20 gauges. So that, is really important to correctly set-up the addresses of the gauges of the string to be read.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"577\" height=\"1024\" src=\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/Digital_node_TIMED-577x1024.png\" alt=\"\" class=\"wp-image-3779\" srcset=\"https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/Digital_node_TIMED-577x1024.png 577w, https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/Digital_node_TIMED-169x300.png 169w, https:\/\/sisgeo.com\/wp-content\/uploads\/2023\/07\/Digital_node_TIMED.png 720w\" sizes=\"(max-width: 577px) 100vw, 577px\" \/><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Sisgeo digital instruments can operate in two powering modes: TIMED or ALWAYS-ON (for more information see F.A.Q.#094).A string of mixed instruments consisting of TIMED gauges and ALWAYS-ON gauges cannot work.The first thing to do is therefore to check that ALL connected instruments in your array are set to TIMED mode.You can check the powering mode [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[584,702,560,678,554,563,578,571,575,711,491],"tags":[230],"class_list":["post-21801","post","type-post","status-publish","format-standard","hentry","category-celdas-de-carga-electricas-para-anclajes","category-d-clinometro-clinometros-digitales-con-tecnologia-mems","category-extensometros-dex-y-extenso-inclinometros-dex-s-es","category-h-level-sistema-de-monitoreo-de-asentamientos","category-inclinometros-fijos-bh-profile","category-inclinometros-fijos-horizontales","category-inclinometros-fijos-mems","category-lt-inclibus-es","category-md-profile-system","category-sensores-tilt-beam-tb","category-wr-log-wireless-dataloggers-es","tag-faq-es"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?\" \/>\n<meta property=\"og:description\" content=\"Sisgeo digital instruments can operate in two powering modes: TIMED or ALWAYS-ON (for more information see F.A.Q.#094).A string of mixed instruments consisting of TIMED gauges and ALWAYS-ON gauges cannot work.The first thing to do is therefore to check that ALL connected instruments in your array are set to TIMED mode.You can check the powering mode [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-24T16:13:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-13T10:04:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#116 &#8211; How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?\",\"datePublished\":\"2023-07-24T16:13:43+00:00\",\"dateModified\":\"2024-09-13T10:04:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\"},\"wordCount\":269,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\",\"keywords\":[\"PREGUNTAS M\u00c1S FRECUENTES\"],\"articleSection\":[\"Celdas de carga el\u00e9ctricas para anclajes\",\"D-CLIN\u00d3METRO \u2013 clin\u00f3metros digitales con tecnolog\u00eda MEMS\",\"Extens\u00f3metros DEX y extens\u00f3-inclin\u00f3metros DEX-S\",\"H-Level - Sistema de monitoreo de Asentamientos\",\"Inclin\u00f3metros fijos BH-Profile\",\"Inclinometros fijos horizontales\",\"Inclin\u00f3metros Fijos MEMS\",\"LT-Inclibus\",\"MD-Profile system\",\"Sensores Tilt Beam (TB)\",\"WR LOG wireless dataloggers\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\",\"url\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\",\"name\":\"FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\",\"datePublished\":\"2023-07-24T16:13:43+00:00\",\"dateModified\":\"2024-09-13T10:04:21+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Productos\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Inclin\u00f3metros in situ IPI\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/inclinometros-in-situ-ipi\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Inclin\u00f3metros Fijos MEMS\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#116 &#8211; How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/es\/#website\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/","og_locale":"es_ES","og_type":"article","og_title":"FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?","og_description":"Sisgeo digital instruments can operate in two powering modes: TIMED or ALWAYS-ON (for more information see F.A.Q.#094).A string of mixed instruments consisting of TIMED gauges and ALWAYS-ON gauges cannot work.The first thing to do is therefore to check that ALL connected instruments in your array are set to TIMED mode.You can check the powering mode [&hellip;]","og_url":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/","og_site_name":"Sisgeo","article_published_time":"2023-07-24T16:13:43+00:00","article_modified_time":"2024-09-13T10:04:21+00:00","og_image":[{"url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png","type":"","width":"","height":""}],"author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Staff Pipeline","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#116 &#8211; How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?","datePublished":"2023-07-24T16:13:43+00:00","dateModified":"2024-09-13T10:04:21+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/"},"wordCount":269,"publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"image":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage"},"thumbnailUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png","keywords":["PREGUNTAS M\u00c1S FRECUENTES"],"articleSection":["Celdas de carga el\u00e9ctricas para anclajes","D-CLIN\u00d3METRO \u2013 clin\u00f3metros digitales con tecnolog\u00eda MEMS","Extens\u00f3metros DEX y extens\u00f3-inclin\u00f3metros DEX-S","H-Level - Sistema de monitoreo de Asentamientos","Inclin\u00f3metros fijos BH-Profile","Inclinometros fijos horizontales","Inclin\u00f3metros Fijos MEMS","LT-Inclibus","MD-Profile system","Sensores Tilt Beam (TB)","WR LOG wireless dataloggers"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/","url":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/","name":"FAQ#116 - How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage"},"image":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage"},"thumbnailUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png","datePublished":"2023-07-24T16:13:43+00:00","dateModified":"2024-09-13T10:04:21+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#primaryimage","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/07\/TIMED_example.png"},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/how-do-i-configure-a-wr-log-digital-node-to-read-rs485-sisgeo-timed-sensors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/"},{"@type":"ListItem","position":2,"name":"Productos","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/"},{"@type":"ListItem","position":3,"name":"Inclin\u00f3metros in situ IPI","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/inclinometros-in-situ-ipi\/"},{"@type":"ListItem","position":4,"name":"Inclin\u00f3metros Fijos MEMS","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/inclinometros-in-situ-ipi\/inclinometros-fijos-mems\/"},{"@type":"ListItem","position":5,"name":"FAQ#116 &#8211; How do I configure a WR-Log digital node to read RS485 Sisgeo TIMED sensors?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/es\/#website","url":"https:\/\/sisgeo.com\/es\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/es\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21801","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/comments?post=21801"}],"version-history":[{"count":1,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21801\/revisions"}],"predecessor-version":[{"id":26052,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21801\/revisions\/26052"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/media?parent=21801"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/categories?post=21801"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/tags?post=21801"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}