{"id":21817,"date":"2023-07-24T18:00:48","date_gmt":"2023-07-24T16:00:48","guid":{"rendered":"https:\/\/sisgeo.com\/sin-categorizar\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"modified":"2023-07-24T18:00:48","modified_gmt":"2023-07-24T16:00:48","slug":"why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","title":{"rendered":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?"},"content":{"rendered":"\n<p>It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge.<\/p>\n\n\n\n<p>For example, suppose a 4-20mA gauge requires at least 12 V to operate correctly and the readout powered with 16 V. The voltage the gauge sees is the voltage supplied by the readout minus the voltage drop in the rest of the current loop. At 20 mA output, the voltage drop across the commonly used 100 ohm resistor is 2 V.<\/p>\n\n\n\n<p>When the voltage supplied by the readout is 16 V, this leaves 14 V for the gauge and everything is fine.<br>However, if the readout is powered with less than 14 V, at 20 mA current it will leave less than 12 V for the gauge. In this case, the output of the transmitter may be in error.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[663,584,587,593,660,705,500,479,476,675,530,467,678,578,485,533,617,623,614,681,629,620],"tags":[230],"class_list":["post-21817","post","type-post","status-publish","format-standard","hentry","category-accesorios-de-prueba-flat-jack","category-celdas-de-carga-electricas-para-anclajes","category-celdas-de-carga-electro-hidraulicas","category-celdas-de-carga-resistiva-para-pruebas-de-pila","category-celdas-de-presion-de-tierra","category-clinometros-analogicos","category-convergence-extensometer-es","category-deformimetros-de-hilo","category-extensometro-a-hilo","category-extensometros-fijos","category-extensometros-miniaturizados-multipunto-mexid","category-fisurometros-y-medidores-de-juntas-es","category-h-level-sistema-de-monitoreo-de-asentamientos","category-inclinometros-fijos-mems","category-mini-omnialog-datalogger-es","category-mpbx-extensometros-de-varilla","category-piezo-resistive-piezometers-es","category-piezometros-con-carcasa-de-titanio","category-piezometros-drive-in","category-sistema-de-control-de-asientos-multipunto","category-transducotres-de-nivel-de-agua","category-transductores-de-presion-removibles","tag-faq-es"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.2 (Yoast SEO v27.2) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge?\" \/>\n<meta property=\"og:description\" content=\"It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-24T16:00:48+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?\",\"datePublished\":\"2023-07-24T16:00:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"},\"wordCount\":171,\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"keywords\":[\"PREGUNTAS M\u00c1S FRECUENTES\"],\"articleSection\":[\"Accesorios de prueba Flat Jack\",\"Celdas de carga el\u00e9ctricas para anclajes\",\"Celdas de carga electro-hidr\u00e1ulicas\",\"Celdas de carga resistiva para pruebas de pila\",\"Celdas de presi\u00f3n de tierra\",\"Clin\u00f3metros anal\u00f3gicos\",\"Convergence extensometer\",\"Deformimetros de hilo\",\"Extens\u00f3metro a hilo\",\"Extens\u00f3metros fijos\",\"Extens\u00f3metros miniaturizados multipunto MEXID\",\"Fisur\u00f3metros y medidores de juntas\",\"H-Level - Sistema de monitoreo de Asentamientos\",\"Inclin\u00f3metros Fijos MEMS\",\"Mini OMNIAlog datalogger\",\"MPBX - Extens\u00f3metros de varilla\",\"Piezo-resistive piezometers\",\"Piezometros con carcasa de titanio\",\"Piezometros Drive-in\",\"Sistema de control de asientos multipunto\",\"Transducotres de nivel de agua\",\"Transductores de presion removibles\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\",\"url\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\",\"name\":\"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#website\"},\"datePublished\":\"2023-07-24T16:00:48+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Productos\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"C\u00e9lulas de presi\u00f3n\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/celulas-de-presion\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Accesorios de prueba Flat Jack\",\"item\":\"https:\/\/sisgeo.com\/es\/category\/products-es-2\/celulas-de-presion\/accesorios-de-prueba-flat-jack\/\"},{\"@type\":\"ListItem\",\"position\":5,\"name\":\"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/sisgeo.com\/es\/#website\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/sisgeo.com\/es\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/sisgeo.com\/es\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\/\/sisgeo.com\/es\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"contentUrl\":\"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\/\/www.pipeline.it\/\"],\"url\":\"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","og_locale":"es_ES","og_type":"article","og_title":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge?","og_description":"It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires [&hellip;]","og_url":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","og_site_name":"Sisgeo","article_published_time":"2023-07-24T16:00:48+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Staff Pipeline","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?","datePublished":"2023-07-24T16:00:48+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"},"wordCount":171,"publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"keywords":["PREGUNTAS M\u00c1S FRECUENTES"],"articleSection":["Accesorios de prueba Flat Jack","Celdas de carga el\u00e9ctricas para anclajes","Celdas de carga electro-hidr\u00e1ulicas","Celdas de carga resistiva para pruebas de pila","Celdas de presi\u00f3n de tierra","Clin\u00f3metros anal\u00f3gicos","Convergence extensometer","Deformimetros de hilo","Extens\u00f3metro a hilo","Extens\u00f3metros fijos","Extens\u00f3metros miniaturizados multipunto MEXID","Fisur\u00f3metros y medidores de juntas","H-Level - Sistema de monitoreo de Asentamientos","Inclin\u00f3metros Fijos MEMS","Mini OMNIAlog datalogger","MPBX - Extens\u00f3metros de varilla","Piezo-resistive piezometers","Piezometros con carcasa de titanio","Piezometros Drive-in","Sistema de control de asientos multipunto","Transducotres de nivel de agua","Transductores de presion removibles"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","url":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/","name":"FAQ#111 - Why I cannot read correctly my 4-20mA current loop gauge? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/es\/#website"},"datePublished":"2023-07-24T16:00:48+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/es\/products-es-2\/fisurometros-y-medidores-de-juntas\/fisurometros-y-medidores-de-juntas-es\/why-i-cannot-read-correctly-my-4-20ma-current-loop-gauge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/es\/geotechnical-and-structural-instrumentation-for-shm\/"},{"@type":"ListItem","position":2,"name":"Productos","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/"},{"@type":"ListItem","position":3,"name":"C\u00e9lulas de presi\u00f3n","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/celulas-de-presion\/"},{"@type":"ListItem","position":4,"name":"Accesorios de prueba Flat Jack","item":"https:\/\/sisgeo.com\/es\/category\/products-es-2\/celulas-de-presion\/accesorios-de-prueba-flat-jack\/"},{"@type":"ListItem","position":5,"name":"FAQ#111 &#8211; Why I cannot read correctly my 4-20mA current loop gauge?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/es\/#website","url":"https:\/\/sisgeo.com\/es\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/es\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/es\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/es\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/es\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/es\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/es\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21817","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/comments?post=21817"}],"version-history":[{"count":0,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/posts\/21817\/revisions"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/media?parent=21817"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/categories?post=21817"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/es\/wp-json\/wp\/v2\/tags?post=21817"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}