{"id":22023,"date":"2023-07-21T17:40:54","date_gmt":"2023-07-21T15:40:54","guid":{"rendered":"https:\/\/sisgeo.com\/non-categorizzato\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/"},"modified":"2023-07-21T17:40:54","modified_gmt":"2023-07-21T15:40:54","slug":"what-can-we-do-when-the-inclinometer-casing-float-during-installation","status":"publish","type":"post","link":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/","title":{"rendered":"FAQ#026 &#8211; What can we do when the inclinometer casing &#8216;float&#8217; during installation?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">If the water filled casing is lighter than grout backfill the uplift force of grout varies with the height of the grout column. If the column is short, the uplift force is low and the casing can be held in place by its own weight or with very little down-force applied from the top. When the grout sets, the bottom cap is isolated from the column of grout and there is no surface for the uplift force to act on. No more than two or three meters to 3 m need to be grouted in the first stage. If the normal bentonite\/cement grout is used it needs to set for at least 12 hours before second-stage grouting.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Avoid use of a quick-set grout, since the heat of hydration could melt and deform the plastic. The two stages can be placed via an outside tremie pipe. Alternatively the first stage can be placed before lowering the casing, provided that all is done efficiently so that there is no chance of the grout setting prematurely.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>If the water filled casing is lighter than grout backfill the uplift force of grout varies with the height of the grout column. If the column is short, the uplift force is low and the casing can be held in place by its own weight or with very little down-force applied from the top. When [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[348,266,233],"tags":[228],"class_list":["post-22023","post","type-post","status-publish","format-standard","hentry","category-tubo-inclinometrico-tipo-ribbed","category-tubo-inclinometrico-tipo-flush","category-tubo-inclinometrico-tipo-quick-joint","tag-faq-it"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6.1 (Yoast SEO v27.6) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FAQ#026 - What can we do when the inclinometer casing &#039;float&#039; during installation? - Sisgeo<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/\" \/>\n<meta property=\"og:locale\" content=\"it_IT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ#026 - What can we do when the inclinometer casing &#039;float&#039; during installation?\" \/>\n<meta property=\"og:description\" content=\"If the water filled casing is lighter than grout backfill the uplift force of grout varies with the height of the grout column. If the column is short, the uplift force is low and the casing can be held in place by its own weight or with very little down-force applied from the top. When [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/\" \/>\n<meta property=\"og:site_name\" content=\"Sisgeo\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-21T15:40:54+00:00\" \/>\n<meta name=\"author\" content=\"Staff Pipeline\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scritto da\" \/>\n\t<meta name=\"twitter:data1\" content=\"Staff Pipeline\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tempo di lettura stimato\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/\"},\"author\":{\"name\":\"Staff Pipeline\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#\\\/schema\\\/person\\\/ad7e82c7990ef88823f081613e1100e2\"},\"headline\":\"FAQ#026 &#8211; What can we do when the inclinometer casing &#8216;float&#8217; during installation?\",\"datePublished\":\"2023-07-21T15:40:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/\"},\"wordCount\":185,\"publisher\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#organization\"},\"keywords\":[\"FAQ\"],\"articleSection\":[\"Tubi inclinometerici\",\"Tubo inclinometrico tipo Flush\",\"Tubo inclinometrico tipo Quick Joint\"],\"inLanguage\":\"it-IT\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/\",\"url\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/\",\"name\":\"FAQ#026 - What can we do when the inclinometer casing 'float' during installation? - Sisgeo\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#website\"},\"datePublished\":\"2023-07-21T15:40:54+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/#breadcrumb\"},\"inLanguage\":\"it-IT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/products-it-2\\\/tubi-inclinometrici\\\/tubo-inclinometrico-tipo-quick-joint\\\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/strumentazione-geotecnica-e-strutturale-per-lo-shm\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Non categorizzato\",\"item\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/category\\\/non-categorizzato\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FAQ#026 &#8211; What can we do when the inclinometer casing &#8216;float&#8217; during installation?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#website\",\"url\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/\",\"name\":\"Sisgeo\",\"description\":\"Inclined to improvement\",\"publisher\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"it-IT\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#organization\",\"name\":\"Sisgeo S.r.l.\",\"url\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"it-IT\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/sisgeodev.pipehosting.it\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/logo-RGB.png\",\"contentUrl\":\"https:\\\/\\\/sisgeodev.pipehosting.it\\\/wp-content\\\/uploads\\\/2023\\\/06\\\/logo-RGB.png\",\"width\":205,\"height\":97,\"caption\":\"Sisgeo S.r.l.\"},\"image\":{\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/#\\\/schema\\\/person\\\/ad7e82c7990ef88823f081613e1100e2\",\"name\":\"Staff Pipeline\",\"sameAs\":[\"https:\\\/\\\/www.pipeline.it\\\/\"],\"url\":\"https:\\\/\\\/sisgeo.com\\\/it\\\/author\\\/staff-pipeline\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FAQ#026 - What can we do when the inclinometer casing 'float' during installation? - Sisgeo","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/","og_locale":"it_IT","og_type":"article","og_title":"FAQ#026 - What can we do when the inclinometer casing 'float' during installation?","og_description":"If the water filled casing is lighter than grout backfill the uplift force of grout varies with the height of the grout column. If the column is short, the uplift force is low and the casing can be held in place by its own weight or with very little down-force applied from the top. When [&hellip;]","og_url":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/","og_site_name":"Sisgeo","article_published_time":"2023-07-21T15:40:54+00:00","author":"Staff Pipeline","twitter_card":"summary_large_image","twitter_misc":{"Scritto da":"Staff Pipeline","Tempo di lettura stimato":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/#article","isPartOf":{"@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/"},"author":{"name":"Staff Pipeline","@id":"https:\/\/sisgeo.com\/it\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2"},"headline":"FAQ#026 &#8211; What can we do when the inclinometer casing &#8216;float&#8217; during installation?","datePublished":"2023-07-21T15:40:54+00:00","mainEntityOfPage":{"@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/"},"wordCount":185,"publisher":{"@id":"https:\/\/sisgeo.com\/it\/#organization"},"keywords":["FAQ"],"articleSection":["Tubi inclinometerici","Tubo inclinometrico tipo Flush","Tubo inclinometrico tipo Quick Joint"],"inLanguage":"it-IT"},{"@type":"WebPage","@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/","url":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/","name":"FAQ#026 - What can we do when the inclinometer casing 'float' during installation? - Sisgeo","isPartOf":{"@id":"https:\/\/sisgeo.com\/it\/#website"},"datePublished":"2023-07-21T15:40:54+00:00","breadcrumb":{"@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/#breadcrumb"},"inLanguage":"it-IT","potentialAction":[{"@type":"ReadAction","target":["https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/sisgeo.com\/it\/products-it-2\/tubi-inclinometrici\/tubo-inclinometrico-tipo-quick-joint\/what-can-we-do-when-the-inclinometer-casing-float-during-installation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/sisgeo.com\/it\/strumentazione-geotecnica-e-strutturale-per-lo-shm\/"},{"@type":"ListItem","position":2,"name":"Non categorizzato","item":"https:\/\/sisgeo.com\/it\/category\/non-categorizzato\/"},{"@type":"ListItem","position":3,"name":"FAQ#026 &#8211; What can we do when the inclinometer casing &#8216;float&#8217; during installation?"}]},{"@type":"WebSite","@id":"https:\/\/sisgeo.com\/it\/#website","url":"https:\/\/sisgeo.com\/it\/","name":"Sisgeo","description":"Inclined to improvement","publisher":{"@id":"https:\/\/sisgeo.com\/it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/sisgeo.com\/it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"it-IT"},{"@type":"Organization","@id":"https:\/\/sisgeo.com\/it\/#organization","name":"Sisgeo S.r.l.","url":"https:\/\/sisgeo.com\/it\/","logo":{"@type":"ImageObject","inLanguage":"it-IT","@id":"https:\/\/sisgeo.com\/it\/#\/schema\/logo\/image\/","url":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","contentUrl":"https:\/\/sisgeodev.pipehosting.it\/wp-content\/uploads\/2023\/06\/logo-RGB.png","width":205,"height":97,"caption":"Sisgeo S.r.l."},"image":{"@id":"https:\/\/sisgeo.com\/it\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/sisgeo.com\/it\/#\/schema\/person\/ad7e82c7990ef88823f081613e1100e2","name":"Staff Pipeline","sameAs":["https:\/\/www.pipeline.it\/"],"url":"https:\/\/sisgeo.com\/it\/author\/staff-pipeline\/"}]}},"_links":{"self":[{"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/posts\/22023","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/comments?post=22023"}],"version-history":[{"count":0,"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/posts\/22023\/revisions"}],"wp:attachment":[{"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/media?parent=22023"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/categories?post=22023"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sisgeo.com\/it\/wp-json\/wp\/v2\/tags?post=22023"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}