FAQ#089 – Which is Gateway model to choose for WR LOG wireless system?

The available gateways for WR LOG system are: – 0LSWR868GW0  – 0LSWR915GW0 – 0LSWR923GW0 These models differ from the frequency utilized by the internal 2G/3G modem. In order to choose for the right gateway, please refer to the document to be downloaded. If more than one model is suggested for the installation Country, you have […]

FAQ#087 – Could the IPI, BH Profile and DEX probes have problems in frozen water?

Sisgeo suggest that frozen water within the inclinometer casings is to be avoided due to following reasons: – Ice within the casing will affect functionality of the systems by blocking the individual probes;– Mechanical damages can occur to the probes, but also to the inclinometer casing due to the expansion of frozen water In any […]

FAQ#086 – ¿Cómo resolver el problema con la conexión remota «dial-up» en Windows con algunos idiomas?

Creando una conexión remota «dial-up» para comunicar con miniOMNIAlog en alguna versión de Windows en lenguas distintas del Italiano e Inglés, puede aparecer un error inherente a los drivers del módem Standard 56000bps utilizado para la conexión. Este problema puede presentarse tanto configurando la conexión manualmente, como utilizando el software proporcionado por SISGEO “miniOMNIAlog Connection […]

FAQ#078 – ¿Es posible enviar un SMS en caso de alarmas con el OMNIAlog?

Si, si el OMNIAlog esta equipado con un modem 2G (GSM/GPRS) modem, conectado a traves del serail del cable a el puerto RS232. El OMNIAlog permite establecer rangos de alarmas y la notificacion de las mimas puede ocurrir: – via SMS; – via email; – via FTP; – aumentando la frecuencia de adquisicion; – manejando […]

Bridge Monitoring on Dnieper River, Kiev, Ukraine

Railway – highway stream crossing with double track railway line and six traffic lanes (three lanes in one direction) across Dnieper River in Kiev City. Total length of the bridge is 1.100 meters. End-of-work scheduled term: end of 2009. Estimated traffic load is more than 300.000 vehicles per day. Load cells are used for monitoring […]

FAQ#077 – Which are the maximum cable lengths from instrument to datalogger?

The cable lengths depend from many factors, first of all installation and cable protections (screen, earth, etc…). Assuming that instruments are installed in a workmanlike, for the maximum cable lengths should be followed the next suggestions: DIGITAL INSTRUMENTS: see FAQ#73 ANALOGUE INSTRUMENTS: see both downloadable documents.

FAQ # 076 – ¿Por qué es necesario añadir una resistencia de terminación para el último sensor digitalizado de cada cadena RS-485?

Todos los instrumentos digitalizados SISGEO (IPI, inclinómetros, H-Nivel …) utilizan el protocolo de comunicación de serie RS-485. El protocolo RS485 contempla una resistencia de terminación. La conexión en cadena recomendada es de nodos de punto-a-punto (multipunto) como un modo BUS (línea). Estrella, anillo o multiplicar la conexión de red no se recomiendan. Los dataloggers SISGEO […]