FAQ#080 – What dimensions has the .CSV file in columns that contains the measures acquired with OMNIAlog and miniOMNIAlog?
The dimensions of the measures file “in columns” downloaded with OMNIAlog and miniOMNIAlog vary according to the number of sensors acquired and the stored cycles of acquisition. The higher is the number of sensors acquired and the number of cycles of acquisition stored, bigger is the dimension of the file. It could be used the […]
FAQ#079 – Is it possible to send SMS in case of alarms with miniOMNIAlog?
Yes, if miniOMNIAlog is equipped with 2G (GSM/GPRS) modem. To do so, the user must have already configured the relative web pages.
FAQ#078 – Is it possible to send SMS in case of alarms with OMNIAlog?
Yes, if OMNIAlog is equipped with a 2G (GSM/GPRS) modem, connected through a serial cable to its RS232 port. OMNIAlog allows to set up alarm thresholds and the notification of these alarms could occur: – by SMS; – by email; – by FTP; – increasing the acquisition frequency; – managing a digital output (for example […]
Bridge Monitoring on Dnieper River, Kiev, Ukraine
Railway – highway stream crossing with double track railway line and six traffic lanes (three lanes in one direction) across Dnieper River in Kiev City. Total length of the bridge is 1.100 meters. End-of-work scheduled term: end of 2009. Estimated traffic load is more than 300.000 vehicles per day. Load cells are used for monitoring […]
FAQ#077 – Which are the maximum cable lengths from instrument to datalogger?
The cable lengths depend from many factors, first of all installation and cable protections (screen, earth, etc…). Assuming that instruments are installed in a workmanlike, for the maximum cable lengths should be followed the next suggestions: DIGITAL INSTRUMENTS: see FAQ#73 ANALOGUE INSTRUMENTS: see both downloadable documents.
FAQ#076 – Why it is necessary add a termination resistor to the last digitized sensor of each RS-485 chain?
All SISGEO digitized instruments (IPIs, Tiltmeters, H-Level…) use the RS-485 serial communication protocol The RS485 protocol contemplate a termination resistor. The recommended chain connection is point-to-point (multidropped) nodes as a bus mode (line). Star, ring or multiply network connection are not recommended. SISGEO dataloggers has already a termination resistor assembled (typically 120Ω). On the opposite […]
FAQ#075 – What parameters are saved in SISGEO digital sensors? What information must the Customer provide when ordering?
All SISGEO digital sensors (e.g. IPI, BH Profile, MD Profile, LT Inclibus, Tilt-meter, RDS, H-Level, etc.) use the Modbus communication protocol over RS-485 serial. SISGEO digital sensors are connected to each other with a single signal cable. The parameters that are configured at the factory for each digital sensor are as follows: Upon confirmation of […]
FAQ#074 – Which kind of datalogger is necessary to read a SISGEO digital sensors?
The sensors are read connecting the end cable to a Modbus Master unit (i.e. OMNIAlog or miniOMNIAlog) with RS-485 interface (DCE, Half duplex, no Echo) able to manage communication with SISGEO Modbus RTU communication protocol. SISGEO’s communication protocol is available for the release upon request. The power [W] of power supply must be chosen according […]
Egnatia Odos Road – Athens, Greece

Egnatia Motorway was designed to the specifications of the Trans-European road network. Across Epirus and Northern Greece from Igoumenitsa to Evros, Egnatia Motorway is one of the largest road construction projects in Europe, 670 kilometres long and 24.5 metres wide.The realisation of this motorway requires the construction of: 50 road interchanges; 350 entrance / exit […]
FAQ#073 – Which is the maximum number of digitized sensors (RS-485, Modbus), the maximum number of chains and the maximum length of cable in a RS-485 network?
Last update: October 2021 All the SISGEO digitized sensors utilize a RS485 interface with Modbus protocol. 1.The maximum number of digitized sensors in a RS-485 network are 247 (theoretical) 2.The maximum number of digitized sensors chains that is possible to connect to Modbus master unit (as OMNIAlog or miniOMNIAlog) are 4. 3. About the maximum […]
FAQ#072 – Why pushing RUN in a miniOMNIAlog webpage with 3G/2G modem the local connection with the PC gets lost?
The loss of the local connection with the PC is normal. This happens because the communication “bus” is the same between PC and miniOMNIAlog and between miniOMNIAlog and 3G/2G modem. Therefore, if you start miniOMNIAlog from the web, the communication is directed towards the 3G/2G modem. This allows to the modem to send SMS, e-mail […]
FAQ#071 – Why miniOMNIAlog is supplied through the PC when it is connected through USB?
This feature allows to not consume the internal batteries during the configuration phase or during the data download. In this way, independently from the duration of the activities above described, the internal batteries are used only during the field activities (acquisition, data dispatch etc). This guarantees a superior duration of exercise.