FAQ#015 – The anchor load value displayed on the load cell manometer or readout does not agree with load calculated by the hydraulic jack. What’s right?
The main factors which influence the anchor measurements are: – axial misalignment of the jack– difference in diameter between the jack and the load cell. These factors cause bending of the bearing plate between the load cell and the jack and affects the response of the cell. To minimise this effect use the genuine distribution […]
FAQ#012 – How is important the function of the grout to the operation of the spider magnets?
The arms of the spider only keep the magnet in place while grouting, but the grout couples the magnet to the surroundig soil. Grout mix shall be controlled (ratio water/cement) during grouting operation according to the soil application.
FAQ#011 – Are the air bubbles present in the liquid mix cause of errors?
Sisgeo liquid mix is de-aired at factory and it is supplied sealed in special tank. However in the DSM reference gauge there is a high sensitive sensor which is able to monitor the weight of the liquid within the reservoir. In the case of the air bubbles come over decreasing the level of the liquid […]
FAQ#010 – Which is the freezing temperature of the Sisgeo liquid mix for H-Levels LLS and Multipoint Settlement Systems system liquid?
Sisgeo liquid is a de-aired water-glycole mix (70% – 30%). The freezing temperature is about -15°C.
FAQ#009 – Can the TEL-310S functioning be influenced from atmospheric conditions?
Any factor (water, mud etc.) that could dirty the internal part of the “SUS” optical sensor unit’s cover can influence the TEL-310S correct functioning. So it is essential to protect properly the “SUS” optical sensor unit from weather conditions, leaving anyway the access possibility for cleaning/maintenance. In any case, TEL-310S has an auto-diagnostics able to […]
FAQ#008 – What is the 0TEL310CAL0 calibration/mounting kit and what is it for?
The 0TEL310CAL0 kit includes a drilling template for the wall where the “ANS” support will be placed, and a template to be placed on the “SUS” optical sensor unit for a possible functional check on field (pendulum’s wire simulation).
FAQ#007 – Are the TEL-310S CUS control unit and the PWS power unit supplied with the fixing kit?
No kit is needed. The “CUS” and “PWS” units are placed in aluminum boxes ready to be fixed on the wall through four M6 screws (not included).
FAQ#006 – Is it possible to use the ANS adjustable support for the pendulum optical manual readout (coordinometer)?
The pendulum readout fixing plate has four holes so it can be fixed, through screws, to the “ANS” adjustable support.
FAQ#005 – Is it possible to fix the ANS adjustable support to the floor?
Since the “ANS” support is articulated, it can be fixed to the floor; this can be useful in case the pendulum’s wire is too far from the walls.
FAQ#004 – Is it possible to place the SUS optical sensor unit with the X axis perpendicular to the wall where the ANS support is fixed?
The TEL-310S telecoordinometer has the following measuring range: To use the “ANS” adjustable support you must have the “X” axis parallel to the wall: so it is not possible to fix the “SUS” optical sensor unit perpendicular to the wall using the “ANS” adjustable support.
FAQ#003 – Which are the needed conditions to use the ANS adjustable support for TEL-310S if you need to monitor the direct pendulum’s wire?
To fix the “SUS” optical sensor unit through the “ANS” support, it is necessary that the direct pendulum’s wire is at a distance of d=230 mm. from the wall. To achieve that, the direct pendulum’s tank has to be placed at a distance of D=20 mm. from the wall: in this way is guaranteed that […]
FAQ#002 – What is the 0TEL310ANS0 adjustable support for TEL-310S and what is it for?
The “ANS” adjustable support (0TEL310ANS0) has been developed to support and fix the “SUS” optical sensor unit (0TEL310SUS0) of the new TEL-310S telecoordinometer. The support is fixed to the wall through two M16 threaded bars, of 370 mm. length (supplied). Once the “SUS” optical sensor unit is fixed to the support, it is possible to […]