FAQ#091 – How can I read data from 0MEPR106000 barometer in engineering units?

The Barometer model 0MEPR106000 have a 4-20mA current loop output.The measuring range is from 800 mbar (equivalent to 4 mA) to 1200 mbar (equivalent to 20 mA). Manual readings are taken connecting the wires to a readout according to the following instructions: Signal: 4-20mA current loop Red: + LoopBlack: – Loop The following formula allows […]

FAQ#090 – Are the old 16/32 ch multiplexers compatible with OMNIAlog?

The available gateways for WR LOG system are: – 0LSWR868GW0  – 0LSWR915GW0 – 0LSWR923GW0 These models differ from the frequency utilized by the internal 2G/3G modem. In order to choose for the right gateway, please refer to the document to be downloaded. If more than one model is suggested for the installation Country, you have […]

FAQ#089 – Which is Gateway model to choose for WR LOG wireless system?

The available gateways for WR LOG system are: – 0LSWR868GW0  – 0LSWR915GW0 – 0LSWR923GW0 These models differ from the frequency utilized by the internal 2G/3G modem. In order to choose for the right gateway, please refer to the document to be downloaded. If more than one model is suggested for the installation Country, you have […]

FAQ#087 – Could the IPI, BH Profile and DEX probes have problems in frozen water?

Sisgeo suggest that frozen water within the inclinometer casings is to be avoided due to following reasons: – Ice within the casing will affect functionality of the systems by blocking the individual probes;– Mechanical damages can occur to the probes, but also to the inclinometer casing due to the expansion of frozen water In any […]

FAQ#086 – ¿Cómo resolver el problema con la conexión remota «dial-up» en Windows con algunos idiomas?

Creando una conexión remota «dial-up» para comunicar con miniOMNIAlog en alguna versión de Windows en lenguas distintas del Italiano e Inglés, puede aparecer un error inherente a los drivers del módem Standard 56000bps utilizado para la conexión. Este problema puede presentarse tanto configurando la conexión manualmente, como utilizando el software proporcionado por SISGEO “miniOMNIAlog Connection […]