Sogamoso hydroelectric project – Colombia
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/04_-_sogamoso_43d73f127faf72b05bb9938f28dccc48.jpg)
Sisgeo worked on the hydroelectric project on Sogamoso river, through Monitoriza, a company of Sisgeo group. Sisgeo supplied and installed all the equipments necessary for this project, located in the north-western area of Colombia, at about 40 km from Bucaramanga. The project concerns the building of a dam 190mt high and 300mt long, of a […]
Monitoring works for the 2014 Sochi Winter Olympic Games – Russia
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/Sisgeo_Sochi_monitoring_projects_24_ca7d07a6f580f16a.jpg)
Sisgeo, thanks to the collaboration with its Russian partners AGT Systems and GPIKO, furnished and installed all the equipments necessary to monitor the most important road and railway works that are under construction in Sochi area, that is the neural centre of 2014 Winter Olympics.The monitored works are: retaining walls for the protection of roads, motorways […]
El Quimbo Hydroelectric project – Colombia
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/el_quimbo_01_63dc952dbb7437849a74d4161e19df12.jpg)
Impregilo is realising in Colombia the hydroelectric power plant of El Quimbo on Magdalena river (in Huila region), on behalf of EMGESA, that is the biggest electric company of the country. The agreement is worth about 250ml of euro. The power plant will have an installed capacity of 400MW. The project includes the building of […]
Sakhalin-2 project Russia
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/01_0ee1096a8344c94114c0afd7487e8584.jpg)
The Sakhalin II project is an oil and gas development project on Sakhalin Island and immediately offshore, in the Sea of Okhotsk, from two fields: Piltun-Astokhskoye and Lunskoye. Piltun-Astokhskoye is primarily an oil field, and Lunskoye is primarily a gas field. The project has been met with heavy criticism over the potential environmental impact, which […]
Cleaning-up project of Panama City and Bay
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/saneamento_panama_05_46e71454870879ec8b7cb8373567fa95.jpg)
The cleaning-up project of Panama City and Bay includes: Construction of Health Service networks Construction and rehabilitation of Collectors and Drive lines Interceptor system Plant for wastewater treatment. These elements will be developed to collect, transport and treat wastewater of Panama City which is currently discharged directly into the bay or rivers and streams in […]
FAQ#111 – Why I cannot read correctly my 4-20mA current loop gauge?
It could be a problem connected to the power supply given by the readout or logger. When the power supply is in the current loop (2-wire gauge) it is necessary to consider the effect of voltage drop across the shunt resistor on the voltage applied to the gauge. For example, suppose a 4-20mA gauge requires […]
FAQ#037 – Which is the linear thermal expansion coefficient of the graduated flat cable (tape) of Water Level Indicators (WLI) and BRS settlement probes?
The linear thermal expansion coefficient of the flat graduated cable is 16x10E-6 m/ °C.
FAQ#033 – I have received the calibration Report of a piezometer. There is not the K Thermal Factor noted. In which way may I proceed?
If the value is not indicated in the Calibration Report, you should use this formula: K = -1 digit/°C For each degree of increase of temperature you should reduce 1 digit.
FAQ#019 – Which is the difference between HAE (high-air entry) and LAE (low-air entry) filters?
HAE (High air entry) filters are normally used to monitor pore pressure in the clay core dams and saturated low permeability soils. “High air entry” means high-resistance to air entry when the filter is saturated. The surface tension of the water in the very fine porus of the filter prevents entry of air. The HAE […]
FAQ#018 – What kind of overvoltage protection is built in the vibrating wire piezometers?
A plasma surge arrestor is wired in parallel with the coil (which is used to pluck the wire). The nominal impulse discharge current 8-20 microsec interval is 10 KA. Impulse spark-over voltage at 1Kv/ microsec: 700 V.
FAQ#017 – Can we buy spare parts for replacement of the water level indicator probe and repair it ourselves?
Yes, we sell a kit which includes instructions, probe, weights, rexin, and any other parts.
Puerto Cabello-La Encrucujada railway project, Venezuela
![](https://e0c48a74.rocketcdn.me/wp-content/uploads/2023/08/01_2cbcc8977d0cacb2a34330c4dc052aa9.jpg)
The section Puerto Cabello – La Encrucijada (Cagua) is part of a more multi-modal and articulated transportation network of freights and passengers. During the first stage of works, the above said section will connect the principal port of the country (Puerto Cabello) to the industrial, agricultural and food poles of Valencia and Maracay. The next […]