FAQ#092 – If I us a WR-LOG wireless system, when data will be available on the Gateway (SLOT TIME) and on my FTP?
WR-LOG system can send three type of data:– Nodes data file– Nodes health file– Compacted or Custom Compacted fileIn order to optimize the availability time, the Sampling Rate (SR) of each node must be inserted into the Gateway, so that Sisgeo STRONGLY SUGGEST to insert the sampling rates of each node into the Gateway.If the […]
FAQ#091 – How can I read data from 0MEPR106000 barometer in engineering units?
The Barometer model 0MEPR106000 have a 4-20mA current loop output.The measuring range is from 800 mbar (equivalent to 4 mA) to 1200 mbar (equivalent to 20 mA). Manual readings are taken connecting the wires to a readout according to the following instructions: Signal: 4-20mA current loop Red: + LoopBlack: – Loop The following formula allows […]
FAQ#090 – Are the old 16/32 ch multiplexers compatible with OMNIAlog?
The available gateways for WR LOG system are: – 0LSWR868GW0 – 0LSWR915GW0 – 0LSWR923GW0 These models differ from the frequency utilized by the internal 2G/3G modem. In order to choose for the right gateway, please refer to the document to be downloaded. If more than one model is suggested for the installation Country, you have […]
FAQ#089 – Which is Gateway model to choose for WR LOG wireless system?
The available gateways for WR LOG system are: – 0LSWR868GW0 – 0LSWR915GW0 – 0LSWR923GW0 These models differ from the frequency utilized by the internal 2G/3G modem. In order to choose for the right gateway, please refer to the document to be downloaded. If more than one model is suggested for the installation Country, you have […]
FAQ#088 – Which is the IP protection class of Sisgeo junction boxes?
Sisgeo junction boxes have IP67 protection.The IP class is granted if the cable glands are correctly tight and the cover is mounted respecting the right key position, as for the following pictures:
FAQ#087 – Could the IPI, BH Profile and DEX probes have problems in frozen water?
Sisgeo suggest that frozen water within the inclinometer casings is to be avoided due to following reasons: – Ice within the casing will affect functionality of the systems by blocking the individual probes;– Mechanical damages can occur to the probes, but also to the inclinometer casing due to the expansion of frozen water In any […]
FAQ#086 – How to solve the problem with dial-up connection under Windows in some languages version
When you create the dial-up remote connection to communicate with miniOMNIAlog, there could appear an error regarding the driver of the Standard Modem 56000bps used for the connection. This error appears only if you use certain versions of Windows in languages different from Italian and English. This problem could appear both configuring manually the connection […]
FAQ#083 – How does the TRIGGER function of OMNIAlog digital input work?
The TRIGGER function of the two digital inputs available on OMNIAlog datalogger is typically used with seismic station. In case of an event (earthquake), the seismic station is usually able to supply a certain tension on its output (typically 5Vdc). If this output is connected to the digital input of OMNIAlog, and OMNIAlog is conveniently […]
FAQ#082 – Is there any precaution to adopt for the number of measurements saved on the OMNIAlog / miniOMNIAlog memory?
OMNIAlog is equipped with a microSD 2GB memory. This memory allows to save a very high number of readings. For this reason, it is necessary to bear in mind what follows: Therefore SISGEO strongly suggests to periodically download data and, later, to delete them from OMNIAlog memory. This way it is guaranteed an efficient data download.
FAQ#081 – Which is the maximum cable length for DEX and DEX-S probes?
The maximum instrument cable length from DEX probe to datalogger is 200 m. If the automatic data acquisition system includes distributed external multiplexer box, the maximum cable length is 200m from DEX probe to multiplexer box plus 200m from multiplexer box to OMNIAlog (in total 400m).
FAQ#080 – What dimensions has the .CSV file in columns that contains the measures acquired with OMNIAlog and miniOMNIAlog?
The dimensions of the measures file “in columns” downloaded with OMNIAlog and miniOMNIAlog vary according to the number of sensors acquired and the stored cycles of acquisition. The higher is the number of sensors acquired and the number of cycles of acquisition stored, bigger is the dimension of the file. It could be used the […]
FAQ#079 – Is it possible to send SMS in case of alarms with miniOMNIAlog?
Yes, if miniOMNIAlog is equipped with 2G (GSM/GPRS) modem. To do so, the user must have already configured the relative web pages.