FAQ#070 – If you disconnect the USB cable from miniOMNIAlog, the datalogger resets. Is it normal?

Yes, it is. This takes place because when you connect the PC though USB connection, miniOMNIAlog is powered by the PC. If you disconnect the USB cable, miniOMNIAlog resets to change its supply source and returns to the supply through internal battery or from an external source (solar panel or electrical supply).