Frequently asked questions

If the TEL-310S was supplied 2 or more month before, will be better to power it for 8 hours before starting to set-up and use it. This is to recharge the back-up battery that give troubles if it is completely discharged.

Any factor (water, mud etc.) that could dirty the internal part of the “SUS” optical sensor unit’s cover can influence the TEL-310S correct functioning. So it is essential to protect properly the “SUS” optical sensor unit from weather conditions, leaving anyway the access possibility for cleaning/maintenance. In any case, TEL-310S has an auto-diagnostics able to […]

The 0TEL310CAL0 kit includes a drilling template for the wall where the “ANS” support  will be placed, and a template to be placed on the “SUS” optical sensor  unit for a possible functional check on field (pendulum’s wire simulation).

No kit is needed. The “CUS” and “PWS” units are placed in aluminum boxes ready to be fixed on the wall through four M6 screws (not included).

The pendulum readout fixing plate has four holes so it can be fixed, through screws, to the “ANS” adjustable support.

Since the “ANS” support is articulated, it can be fixed to the floor; this can be useful in case the pendulum’s wire is too far from the walls.

The TEL-310S telecoordinometer has the following measuring range: To use the “ANS” adjustable support you must have the “X” axis parallel to the wall: so it is not possible to fix the “SUS” optical sensor unit perpendicular to the wall using the “ANS” adjustable support.

To fix the “SUS” optical sensor unit through the “ANS” support, it is necessary that the direct pendulum’s wire is at a distance of d=230 mm. from the wall. To achieve that, the direct pendulum’s tank has to be placed at a distance of  D=20 mm. from the wall: in this way is guaranteed that […]

The “ANS” adjustable support (0TEL310ANS0) has been developed to support and fix the “SUS” optical sensor unit (0TEL310SUS0) of the new TEL-310S telecoordinometer. The support is fixed to the wall through two M16 threaded bars, of 370 mm. length (supplied). Once the “SUS” optical sensor unit is fixed to the support, it is possible to […]

It is possible to use the pendulum optical manual readout instead of TEL-310S “SUS”  optical sensor unit without any regulation of the “ANS” support. It is also possible to start the pendulum’s monitoring with the pendulum optical manual readout and then automate the readings with TEL-310S telecoordinometer , without changing its initial zero.